الجودة محول طاقة محدب رباعي الأبعاد 4D3C-L من GE للإصلاح مصنع

محول طاقة محدب رباعي الأبعاد 4D3C-L من GE للإصلاح

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged.SolutionReplace the dome, dome tube; repair electric motor ►Common issues with 4D3C-L 4D

الجودة مسبار قلبي S5-2 للإصلاح مصنع

مسبار قلبي S5-2 للإصلاح

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain relief ► Common issues with S5-2 Cardiac probe Poor or blurry images Constant noise or static Color streaking or intermittent artifacts Cracked or dried-out lens Cable or strain

الجودة منظار الصدر Olympus LTF-160 للإصلاح مصنع

منظار الصدر Olympus LTF-160 للإصلاح

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. Solution: Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. ►Problem &

الجودة "أوليمبوس CF- H180AL" "مناظر القولون الإلكترونية للإصلاح" مصنع

"أوليمبوس CF- H180AL" "مناظر القولون الإلكترونية للإصلاح"

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed. 5. The light guide tube is slightly wrinkled. Solution: Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire,

الجودة مسبار البطن GE 4C-RS للإصلاح مصنع

مسبار البطن GE 4C-RS للإصلاح

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

الجودة Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube مصنع

Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube

Olympus/ Pentax/ Fuji A/W Tube ► Brief Description The "air/water channel" is a critical part of a flexible endoscope's function. The tube you are referring to is most commonly known as the Air/Water Valve Tube or A/W Tube . It's a small, transparent, and highly flexible tube that connects the air and water valves on the control body of the endoscope to the internal channel that runs the length of the insertion tube. ► 1. Primary Purpose and Function This single, transparent

الجودة غطاء أندوسكوب أوليمبوس لـ CF-Q160AL مصنع

غطاء أندوسكوب أوليمبوس لـ CF-Q160AL

Olympus Endoscope Insertion Tube Boot For CF-Q160AL ► Brief Description The Insertion Tube Boot (also referred to as the Strain Relief Boot or Sleeve) is a critical protective component located at the junction between the control handle and the flexible insertion tube of the Olympus CF-Q160AL colonoscope. ► Features Strain Relief & Kink Prevention: It provides a graduated transition from the rigid control handle to the flexible insertion tube. This prevents sharp bends at the

الجودة غطاء جسم Endoscope المرن لـ Olympus TJF-160VR مصنع

غطاء جسم Endoscope المرن لـ Olympus TJF-160VR

Flexible Endoscope body cover for Olympus TJF-160VR ► Brief Description The body cover of the Olympus TJF-160VR is a critical component designed to ensure ergonomic comfort, durability, and protection for the endoscope's operational controls during clinical procedures. It is engineered to withstand frequent disinfection cycles and mechanical stress while maintaining optimal functionality. ► Features Ergonomic Design​ Protection and Durability Operational Efficiency Hygiene

الجودة أجزاء مرنة للمنظار الداخلي (أوليمبوس MAJ-207) صمام امتصاص مصنع

أجزاء مرنة للمنظار الداخلي (أوليمبوس MAJ-207) صمام امتصاص

Olympus MAJ-207 SUCTION VALVE ► Brief Description The Olympus MAJ-207 Suction Valve is a critical accessory designed for use with Olympus endoscopes, enabling precise control over suction during endoscopic procedures. ► Features The primary function of the MAJ-207 is to allow the endoscope operator to control the suction function. By pressing or releasing the valve, the operator can open or close the suction channel of the endoscope. It is designed to enable controlled