flexible endoscope medical device repair training

"
الجودة مسبار خطي L15-7io للإصلاح مصنع

مسبار خطي L15-7io للإصلاح

L15-7io Linear probe for repair ► Brief Description Fault: Lens problem. Solution: Replace probe lens. ►Problem & Solutoin Model L15-7io Fault Lens problem Solution Replace probe lens ► Common issues with L15-7io probe Cable and Connector Issues Acoustic Lens Damage Crystal/Element Failure Housing/Physical Damage Oil Leak If your instrument has any of the above problems or others, please feel free to contact us for assistance. We will do our best to help you solve the issue.

الجودة (أوليمبوس A70940A) جهاز التشعب الذاتي للاصلاح مصنع

(أوليمبوس A70940A) جهاز التشعب الذاتي للاصلاح

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

الجودة "أوليمبوس CF- H180AL" "مناظر القولون الإلكترونية للإصلاح" مصنع

"أوليمبوس CF- H180AL" "مناظر القولون الإلكترونية للإصلاح"

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed. 5. The light guide tube is slightly wrinkled. Solution: Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire,

الجودة محول طاقة محدب رباعي الأبعاد 4D3C-L من GE للإصلاح مصنع

محول طاقة محدب رباعي الأبعاد 4D3C-L من GE للإصلاح

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged.SolutionReplace the dome, dome tube; repair electric motor ►Common issues with 4D3C-L 4D

الجودة منظار الصدر Olympus LTF-160 للإصلاح مصنع

منظار الصدر Olympus LTF-160 للإصلاح

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. Solution: Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. ►Problem &

الجودة لوحة تشغيل CCD لمنظار أوليمبوس GIF-H170 مصنع

لوحة تشغيل CCD لمنظار أوليمبوس GIF-H170

CCD driver board for Olympus GIF-H170 Endoscop ► Brief Description The CCD driver board is a critical component in the Olympus GIF-H170 endoscope, responsible for controlling the charge-coupled device (CCD) that captures images during endoscopic procedures . ► Features Compatibility : Specifically designed for the Olympus GIF-H170 video gastroscope Function : Controls the CCD sensor that provides high-resolution imaging Signal Processing : Handles video signal transmission

الجودة منظار أوليمبوس TJF-160VR للإصلاح مصنع

منظار أوليمبوس TJF-160VR للإصلاح

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. Solution: Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube,

الجودة R وولف 7326071 منظار البول لإصلاحه مصنع

R وولف 7326071 منظار البول لإصلاحه

R Wolf 7326071 ureteroscope for repair ► Brief Description Fault: The image has spots,image bundle aging,light bundle broken;Insert tube aging;Biopsy channel worn and leakage;Bending section,wire and helix tube were worn. Solution: Replace the light bundle,image bundle,rubber,biopsy channel,helix tube,wire. ►Problem & Solutoin Brand R Wolf Model 7326071 Fault The image has spots,image bundle aging,light bundle broken;Insert tube aging; Biopsy channel worn and leakage;Bending

الجودة مسبار الموجات فوق الصوتية ذو المصفوفة الخطية Aloka UST-5413 للإصلاح مصنع

مسبار الموجات فوق الصوتية ذو المصفوفة الخطية Aloka UST-5413 للإصلاح

Aloka UST-5413 linear array ultrasound probe for repair ► Brief Description Fault: Lens break. Solution: Replace lens. ►Problem & Solutoin BrandAlokaModelUST-5413FaultLens breakSolutionReplace lens ► Common issues with UST-5413 Probe Image dropouts or black linesAcoustic lens damageCable damageConnector damageWeak or noisy image ►FAQ How can we prevent the acoustic lens on the UST-5413 from peeling after a repair? Avoid Solvent Cleaners: Never use solutions containing high