logo
Found 90 products for "

dynamical system cable

"
الجودة M1941A كابل تمديد SpO2 لمراقبة المرضى مصنع

M1941A كابل تمديد SpO2 لمراقبة المرضى

M1941A SpO2 Extension Cable For Patient Monitors ► Brief Description The M1941A (often referred to as the M1941A SpO2 Adapter Cable) is a medical-grade extension cable designed to connect patient monitors with compatible SpO2 (pulse oximetry) sensors. It acts as a crucial intermediary link, ensuring accurate, real-time transmission of oxygen saturation and pulse rate data from the patient to the monitoring system. ► Features Stable Signal Transmission Plug-and-Play Compatibil

الجودة جهاز Anschlusskabel Flow Sensor Drager (93) 8416600-13 لجهاز التهوية من سلسلة Evita/Savina مصنع

جهاز Anschlusskabel Flow Sensor Drager (93) 8416600-13 لجهاز التهوية من سلسلة Evita/Savina

Anschlusskabel Flowsensor Drager (93)8416600-13 For Evita Series/Savina Ventilators ► Brief Description For the Drager (93)8416600-13 (often cross-referenced with P/N 8411794), this is the specialized interface cable used to connect the flow sensor to the ventilation unit. ►Features Signal Transmission Power Supply Plug-and-Play (Self-Locking) EMI Shielding Hot-Wire Anemometry Support Flexible Deployment ► Specification Brand Drager Part Number (93)8416600-13 Condition

الجودة أداة إصلاح لـ Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd كابل مصنع

أداة إصلاح لـ Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd كابل

REPAIR TOOLS FOR OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD CABLE Brand: OLYMPUS Model: OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD Condition: Brand new A repair tool that can be used to repair OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD cable. It can be securely fixed and easy to repair cable. We provide trading and service of Ultrasound unit/Transducer, Dynamic system device/parts, Rigid endoscope parts and Flexible endoscope parts, we

الجودة رأس الكاميرا OLYMPUS OTV-S6H-1D للإصلاح مصنع

رأس الكاميرا OLYMPUS OTV-S6H-1D للإصلاح

Olympus OTV-S6H-1D Camera Head For Repair ► Brief Description Fault: 1.Image yes. 2.Cable aging and interference Solution: Replace new cable. ►Problem & Solutoin Brand Olympus Model OTV-S6H-1D Fault Cable aging and interference Solution Replace cable ► Applications Laparoscopy (abdominal surgery) Arthroscopy (joint surgery) ENT (Ear, Nose, Throat) procedures General endoscopic imaging ► Troubleshooting & Support If the camera is not functioning, check: Cable connections

الجودة مسبار محدب C5-2 لأجزاء الأجهزة الطبية للإصلاح مصنع

مسبار محدب C5-2 لأجزاء الأجهزة الطبية للإصلاح

C5-2 Convex Probe For Repair ► Brief Description Fault: Strain relief damage, cable broken. Solution: Replace strain relief, repair cable. ►Problem & Solutoin Model C5-2 Convex Fault Strain relief damage, cable broken Solution Replace strain relief, repair cable ► Common Issues with C5-2 Probes Dead or flickering elements (image dropouts, black lines) Cable damage (broken wires near the connector or handle) Lens damage (cracks, delamination, or wear) Acoustic array failure

الجودة BK طبي 9096 مسبار الموجات فوق الصوتية الروبوتية للإصلاح مصنع

BK طبي 9096 مسبار الموجات فوق الصوتية الروبوتية للإصلاح

BK Medical 9096 Robotic Ultrasound Probe For Repair ► Brief Description Fault: All the outer skin of the cable is seriously damaged. Solution: Replace the outer skin of the cable. ►Problem & Solutoin Brand BK Medical Model 9096 Fault All the outer skin of the cable is seriously damaged Solution Replace the outer skin of the cable ► Common issues with 9096 Probes Cable Damage Acoustic Lens/Membrane Damage Probe Housing Damage Crystal Array Damage Robotic Grasping Interface

الجودة (سترايكر) 1188-210-105 رأس الكاميرا للإصلاح مصنع

(سترايكر) 1188-210-105 رأس الكاميرا للإصلاح

STRYKER 1188-210-105 camera head for repair ► Brief Description Fault: Image with interrupt. Cable aging. Solution: Replace compatible new cable and connector. ►Problem & Solutoin Brand STRYKER Model 1188-210-105 Fault Image with interrupt. Cable aging Solution Replace compatible new cable and connector ► Common issues with 1188-210-105 camera head Image Quality Problems Physical and Cable Damage Button and Control Malfunctions Overheating If your instrument has any of the

الجودة مسبار البطن GE 4C-RS للإصلاح مصنع

مسبار البطن GE 4C-RS للإصلاح

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

الجودة مسبار قلبي S5-2 للإصلاح مصنع

مسبار قلبي S5-2 للإصلاح

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain relief ► Common issues with S5-2 Cardiac probe Poor or blurry images Constant noise or static Color streaking or intermittent artifacts Cracked or dried-out lens Cable or strain

Previous
Page 5 من 10
Next