الجودة أليمبوس CF-HQ190L أدوات طبيّة أدوات إصلاح مصنع

أليمبوس CF-HQ190L أدوات طبيّة أدوات إصلاح

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not good sealed and leaking. Solution: Replace biopsy channel, bending section, wire, helix tube, light guide tube, rubber Company Profile Guangzhou Careutech Co., Ltd. supplies medical

الجودة معالج الفيديو الـ (PENTAX Medical EPK-i7000) للإصلاح مصنع

معالج الفيديو الـ (PENTAX Medical EPK-i7000) للإصلاح

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: Six months. ►Problem & Solution Brand PENTAX Model EPK-i7000 Product Processor Fault It cannot recognize the endoscope and reports an error. Solution Repair the system board. ►

الجودة محول طاقة محدب رباعي الأبعاد 4D3C-L من GE للإصلاح مصنع

محول طاقة محدب رباعي الأبعاد 4D3C-L من GE للإصلاح

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged.SolutionReplace the dome, dome tube; repair electric motor ►Common issues with 4D3C-L 4D

الجودة مسبار قلبي S5-2 للإصلاح مصنع

مسبار قلبي S5-2 للإصلاح

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain relief ► Common issues with S5-2 Cardiac probe Poor or blurry images Constant noise or static Color streaking or intermittent artifacts Cracked or dried-out lens Cable or strain

الجودة منظار الصدر Olympus LTF-160 للإصلاح مصنع

منظار الصدر Olympus LTF-160 للإصلاح

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. Solution: Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. ►Problem &

الجودة "أوليمبوس CF- H180AL" "مناظر القولون الإلكترونية للإصلاح" مصنع

"أوليمبوس CF- H180AL" "مناظر القولون الإلكترونية للإصلاح"

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed. 5. The light guide tube is slightly wrinkled. Solution: Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire,

الجودة مسبار البطن GE 4C-RS للإصلاح مصنع

مسبار البطن GE 4C-RS للإصلاح

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

الجودة سونوسكيب EG-500 التنظير الغذائي الإلكتروني للإصلاح مصنع

سونوسكيب EG-500 التنظير الغذائي الإلكتروني للإصلاح

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The angle is seriously insufficient and tight, with wear on the snake bone, steel wire, and helix tube; 6. The light guide tube has dents; 7. The handle shell is cracked and has severe

الجودة T-A0010 أداة إصلاح رأس الكاميرا لكارل ستورز الصورة 1 HD H3-Z 22220055 رأس الكاميرا مصنع

T-A0010 أداة إصلاح رأس الكاميرا لكارل ستورز الصورة 1 HD H3-Z 22220055 رأس الكاميرا

T-A0010 Repair tool for Karl Storz Image 1 HD H3-Z 22220055 Camera Head Product Description 1.Introduction T-A0010 Repair tool for Karl Storz Image 1 HD H3-Z 22220055 Camera Head Brand-new Perfectly repair camera head without scratch 2. Characteristics and Advantages Number:T-A0010 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Aluminium Alloy Weight: 2.1KG 3. Functions: Disassembly and assembly 4